Sound Measurement

 

We provide our customers sound measurement and assessment. This includes but not limited to the folllowing:

1. Establish 1/1 and 1/3 octave band sound pressure level of machines in accordance to ISO 6798 and 3746. Frequency ranges from 31.5 Hz up to 10 KHz

2. Third party sound measurement and certification.

3. Test and verify sound pressure levels at industrial and residential sites in accordance to OSHA standards.

 

   
   

 

Applicable standards IEC 60651 Type2, IEC 60804 Type2, BS EN 6065, 1994, IEC 1260-1995
Microphone 1/2-inch Electret condenser microphone
Accuracy +/- 1.5dB (ref 94dB @ 1KHz)
Measurement range 30dB to 130dB
Measurement function Lp , Leq , LE , Lmax , Lmin
Frequency range 25Hz ~ 10KHz
Frequency weighting A ,C, Flat
Time weighting Fast , Slow
1/1- 1/3 Analyzer level range 5 ranges in 10-dB step, 20-90dB/ 30-100dB/ 40-110dB/ 50-120dB/ 60-130dB
1/1 Octave and 1/3 Octave band filters 1/1 Octave band center frequencies : (9 bands)
31.5Hz, 63Hz, 125Hz, 250Hz, 500Hz, 1KHz, 2KHz, 4KHz, and 8KHz.
1/3 Octave band center frequencies : (27 bands)
25Hz, 31.5Hz, 40Hz, 50Hz, 63Hz, 80Hz, 100Hz,
125Hz, 160Hz, 200Hz, 250Hz, 315Hz, 400Hz, 500Hz,
630Hz, 800Hz, 1KHz, 1.25KHz, 1.6KHz, 2KHz, 2.5KHz,
3.15KHz, 4KHz, 5KHz, 6.3KHz, 8KHz 10KHz.

 

 

Home    About us    Contact us    Diesel Generators    Sound Attenuation    NEC Training